When EMC matters, the world calls TESTUPS!

Turnkey EMC labs, built around a chamber you can afford, relocate and validate.

3 m and 10 m standard; 5, 20 or 30 m custom, per project. One contract, one team: chamber, test systems, software, validation and training.

30+
Countries Served
5+
Chambers Delivered
22+
Years of Experience
24/7
Global Support
In stock in the USA

TPF205A-30 Power Line EMI Filter

Shield-wall (bulkhead) power line EMI filter — buy online and ship fast from US stock. US shipping included.

20 units in stockShips from ConnecticutFrom $750/unitCE · cULus ListedOffer valid until December 31, 2026
View pricing & buy

When EMC matters,
the world calls TESTUPS!

EMC Knowledge
Compliant with EMC Standards
Global Testing Solutions
The Turnkey Advantage

Inside a Turnkey EMC Lab

A turnkey EMC lab is far more than a shielded room. It is a complete EMC test environment — semi-anechoic chamber, instrumentation, software and calibration — delivered as one integrated system, on one contract, by one team.

TESTUPS delivers the whole compliance ladder in one place: from in-house pre-compliance screening to full compliance testing — with the chamber, test systems and quiet zone engineered around the products you certify.

At its heart is a TESTUPS-specified anechoic chamber, built with our manufacturing partners and custom-sized for your products (3 m and 10 m standard; 5, 20 or 30 m custom, per project), designed to be affordable, relocatable and validated to the standards you test against.

Pyramidal RF absorbersConductive ground planeEUT turntableBiLog antenna mastLive compliance sweep
Interactive 3D model of a TESTUPS turnkey semi-anechoic EMC chamber — RF absorbers, ground plane, EUT turntable and BiLog antenna
Explore in interactive 3D
Example: 3 m semi-anechoic chamber · explore it in 3D

A 3:20 walkthrough

Semi-anechoic chamber, shielded room, emissions and immunity test systems, and control room.

3D visualization
  • Semi-anechoic chamber: Example: 3 m semi-anechoic chamber, 9 × 6 × 6 m (29.5 × 19.7 × 19.7 ft). Every TESTUPS chamber is custom-sized, and its frequency range is set for each project. Designed for CISPR 16 site validation. TESTUPS antennas cover 10 Hz – 40 GHz in total. A shielded room lined with absorbers, where a product's radio emissions are measured without reflections from the walls and ceiling.
  • Control room: The engineers run the tests and read the measurements here, outside the chamber, so they do not influence the results.
  • Amplifier room: Holds the power amplifiers that drive the field-generating antenna during immunity tests.
  • Shielded room: A metal enclosure that keeps outside radio signals away from the test. Here it holds the conducted immunity test system.
  • Storage: Antennas, cables and transport cases wait here between tests.
  • Office: Where test plans and reports are written.
  • RF shielded door: 1 × 2 m, with automatic and manual operation. When it closes, it completes the metal shield around the chamber.
  • RF absorbers: The blue pyramids absorb radio waves, so reflections from the walls and ceiling do not distort the measurement. The chamber then behaves like an open-air test site.
  • Turntable with the device under test: The turntable rotates the device so that its emissions can be measured from every side.
  • Antenna mast: The mast moves the antenna up and down to find the height of the strongest emission.
  • Field-generating antenna: In an immunity test it exposes the device to a controlled radio field, to see whether the device keeps working.
  • Field probe: It measures the strength of the radio field in the test area.
  • Measuring instruments: Receivers and signal generators in the racks record what the antenna picks up in the chamber.
  • Test software: The engineers follow the measurement live on these screens.
  • Power amplifiers: Amplifiers of the radiated immunity test system. They drive the field-generating antenna in the chamber.
  • RF I/O wall panel: The amplifier output passes through the shielded wall to the antenna in the chamber.
  • Conducted immunity test bench: Disturbances are injected onto the cables of the device under test, which stands over a metal ground plane.

3D visualization. A 3:20 video walkthrough of a TESTUPS turnkey EMC laboratory, showing the semi-anechoic chamber, a shielded room, the emissions and immunity test systems, and the control room.

TESTUPS turnkey EMC lab — 3:20 walkthrough

The complete laboratory

Everything a lab needs to test, pass and prove compliance is designed together so the pieces work as a system from day one — sized to your products and the standards you certify against.

  • Custom-sized, relocatable semi- or fully-anechoic chamber
  • Emissions & immunity test systems
  • Automated EMC measurement software
  • Calibration, NSA & site validation
  • Operator training & documentation
  • Lifecycle service & support

Turnkey EMC test systems

Emissions and immunity instrumentation — integrated, automated and calibrated — so an operator runs a full standard sequence from software and gets a witness-quality report, not a rack of parts to wire together.

  • Radiated & conducted emissions (CISPR, FCC, CE)
  • Radiated & conducted immunity (RI, BCI)
  • ESD, EFT/burst, surge & voltage dips
  • EMI receivers, amplifiers & antennas
  • LISNs, CDNs & transient generators
  • Turntables, antenna masts & positioners

From site survey to first measurement

01
Site survey

We assess your facility, target standards and test envelope.

02
Design

Chamber, systems and layout engineered to your requirements.

03
Manufacture

Shielding, absorbers and instrumentation built and pre-tested.

04
Install

On-site assembly of the chamber, systems and infrastructure.

05
Commission

FAT/SAT, NSA mapping and field-uniformity validation.

06
Train & support

Operator training, documentation and lifecycle service.

See a turnkey lab — then test one yourself

Walk through an example 3 m semi-anechoic chamber in interactive 3D, then run a live radiated-emissions test in your browser, using the same physics a real EMC lab measures.

Why the TESTUPS chamber is different

A test chamber has to fit your budget and still pass the site validation that accredited testing relies on. A TESTUPS chamber is specified to do both: sized to your budget, with on-site validation to CISPR 16-1-4 available.

Affordable

Pre-compliance EMC anechoic chambers start from $200,000 (7 × 4 × 3 m / 23 × 13 × 10 ft). Modular construction cuts factory cost, shipping and installation time.

Movable

Bolted, modular steel panels. If your lab moves, the chamber can be dismantled and reinstalled at the new site. Relocation is available on request, per project.

High grade

Hybrid ferrite + pyramidal absorbers, RF shielding and RF-gasketed doors, specified by TESTUPS and built with our manufacturing partners. Shielding effectiveness and frequency range are set per project and stated in the quote.

Standard compliant

Designed for the standards named in your project, for example FCC Part 15 (measured to ANSI C63.4), CISPR 32 / EN 55032 and CISPR 25. On-site validation to CISPR 16-1-4, IEC 61000-4-3 and IEEE 299 is available where in scope, with the validator named in the quote. MIL-STD-461 can be specified.

See TESTUPS in Action

Watch how we deliver complete EMC solutions worldwide

Turnkey EMC laboratories by TESTUPS

Playing loads the video from YouTube (Google) via youtube-nocookie.com. See our Privacy Policy.

Turnkey EMC Laboratories

Complete laboratory solutions from design to compliance testing

EMC Test Systems and EMC Anechoic Chambers by TESTUPS

Playing loads the video from YouTube (Google) via youtube-nocookie.com. See our Privacy Policy.

EMC Test Systems & Chambers

Professional test systems and anechoic chambers

EMC Anechoic Chamber Services by TESTUPS

Playing loads the video from YouTube (Google) via youtube-nocookie.com. See our Privacy Policy.

Anechoic Chamber Services

Refurbishment, relocation, and installation services

Standards We Cover

CISPR 16CISPR 25IEC 61000-3-2IEC 61000-4-3RTCA DO-160EN 55032FCC Part 15ISO 11452
Upcoming Exhibition
EMC Hungary 2027

Meet TESTUPS at EMC Hungary 2027

EMC Hungary 2027 (EMCH2027) — International Conference on Electromagnetic Compatibility

Symposium: April 12–14, 2027 · Kecskemét, Hungary

Frequently asked questions

What is a turnkey EMC lab?

A complete EMC test facility delivered by one supplier on one contract: shielded anechoic chamber, emissions and immunity test systems, software, calibration, site validation where in scope, and operator training. TESTUPS delivers turnkey EMC labs, specified by TESTUPS and built with our manufacturing partners, worldwide; in the US through TESTUPS, LLC, Boston, MA.

What does "3 m" or "10 m" chamber mean?

It is the measurement distance between the antenna and the product under test, not the size of the room. 3 m and 10 m are the standard distances; 5, 20 or 30 m chambers are custom, per project.

How big is an EMC anechoic chamber?

It depends on the measurement distance, the largest product you test and your building. Every TESTUPS chamber is custom-sized. For example, the TESTUPS SAC-9660 3 m semi-anechoic chamber measures 9 × 6 × 6 m (29.5 × 19.7 × 19.7 ft).

Can an EMC anechoic chamber be moved?

Yes, if it is built from bolted modular panels. TESTUPS chambers are designed to be dismantled and reinstalled. Relocation, reinstallation and, if you want it, site validation are available on request, per project.

Which standards is a TESTUPS chamber designed for?

The standards named in your project, for example FCC Part 15 (measured to ANSI C63.4), CISPR 32 / EN 55032 for multimedia equipment and CISPR 25 for automotive components. On-site validation to CISPR 16-1-4 (NSA, sVSWR), IEC 61000-4-3 and IEEE 299 is available where in scope, with the validator named in the quote.

How much does an EMC anechoic chamber cost?

A TESTUPS pre-compliance EMC anechoic chamber (7 × 4 × 3 m / 23 × 13 × 10 ft) starts from $200,000. Full-compliance chambers are priced by measurement distance (3 m and 10 m standard; 5, 20 or 30 m custom), chamber size, shielding and absorber specification, and validation scope.

How long does a turnkey EMC lab take?

It depends on size and scope. The lead time is stated in the quote after the site survey.

Ready to solve your EMC challenges?

Contact our team of EMC experts for tailored solutions.